Trunking FAQs

Which D-Line cable trunking should I select?

The choice of trunking should consider the volume of cables being concealed. Check the D-Line trunking dimensions provide sufficient capacity for your requirements.

Note product dimensions are external dimensions - please consider wall thickness of D-Line Cable Trunking is typically 1mm; in other words 30x15mm Cable Cover will have internal dimensions approx. 28x13mm (1mm for lid & 1mm for base).

Any tips for measuring up?

Remember to leave space (between D-Line lengths) to accommodate accessory required. For smooth-fit accessories, including connectors for all sizes, use the accessory as the template. Pencil mark the surface and the length, to indicate precisely where the trunking needs to be reach. After installing the lengths, and inserting the cables, the smooth-fit accessory will retro-fit into the space(s) you left.

If using Clip-Over bends and tees accessories, the gaps do not have to be precise; but ensure the lengths are spaced so the rear tabs will grip i.e. the lengths are not too far apart! Then it is easy to attach the corner bends or tee accessory.

Any tips for cutting D-Line Trunking lengths?

For best results use a junior hacksaw and - if preferred - cutting block to help keep blade straight. If using Smooth-Fit Micro 16x8mm Accessories and Connectors (all sizes) a straight cut is important, so the accessory can fit neatly up to the length. If using Clip-Over Accessories, cutting and measuring doesn’t need to be as precise, as the accessories allow a 10mm tolerance.

Pictures show the click-lock at the top side. Can it be at the base instead?

Yes, an installation can be reversed, but the lid then no longer acts as a cable retainer. Installers usually prefer the hinge at the base, so cables are not dropping out along the way!

How many times can the hinge be opened?

D-Line lengths can be opened and closed thousands of times, making it easy to later add or remove cables if required. The hinge is tensioned so it is not too stiff or slack, making D-Line easy to handle.

Can you rely on the self-adhesive for permanent fixing?

D-Line tapes give a strong bond, so take care before securing to the surface. It is possible that tapes can eventually lose effectiveness as adhesive elements vaporise over time, but we have known our cable cover lengths stuck to smooth clean surfaces (by our self-adhesive) for many years. If using a larger cable trunking (such as our 50mm x 25mm for wall mounted TVs) then because of the greater weight and strain on the tape, we advise installers to also use a secondary fixing (wall plug & screw) spaced every 30cm.

How do I remove D-Line Trunking from my wall?

Please remove with caution as adhesive backing does create a strong bond. To remove, slowly pull the trunking from the wall, using a wallpaper scraper or sharp knife behind the adhesive to slowly peel away… then for any additional residue left, use an adhesive removal spray.

I can’t find the colour I want, can I paint D-Line Trunking?

Yes! All D-Line Trunking lengths & accessories are fully paintable. Before painting, key the surface with a fine sandpaper & apply two coats of paint.

Cable Tidy Unit FAQs

What size Cable Tidy Unit do I need for my extension block?

Use large unit to contain popular 6-gang extension sockets up to 340mm length. Use small unit to contain popular 4-gang extension sockets up to 280mm length.

How do I open a Cable Tidy Unit?

Pull-out the rear side wall of the Cable Tidy Unit slightly - to allow for easy removal of the lid.

Will using a D-Line Cable Tidy Unit cause a fire risk?

No! D-Line Cable Tidy Units are produced from electrically safe ABS plastic & have been fully safety tested and certified to BS EN 60670-22:2006.

How do I hide cables coming from Cable Tidy Units?

D-Line Trunking can be used to hide entry/exit cables.

Can you paint a Cable Tidy Unit?

You can paint, only with a spray paint suitable for plastics.

Where are D-Line Cable Tidy Units made?

D-Line Cable Tidy Units are proudly Made in UK, from high quality robust ABS plastic.

Floor Cable Protector FAQs

I need to cover a trailing cable… what type of Floor Cable Cover should I use?

Firstly, you need to determine the total outer width x diameter of the cables you’re looking to cover. Once you’ve identified a Floor Cable Cover that has a sufficient sized cable cavity, you’ll then need to choose based on the type of traffic the floor cover will be subject to… for light or infrequent amounts of pedestrian traffic use Light Duty Floor Cable Cover. For protecting cables under regular foot traffic, Medium Duty Cable Protector provides effective protection.

I need to cover cables less than 1.8m – can I shorten D-Line Floor Cable Covers?

Yes! Light & Medium Cable Protector Lengths can be cut to size, using a sharp Stanley knife. Heavy Duty Cable Protector cannot be cut to size.

I need to cover an exact length of cable – can lengths be ordered to the exact length required?

No, D-Line Floor Cable Protector lengths are available in 1.8m, 4.5m & 9m length options for Light/Medium Duty. Note, Medium Duty Cable Protectors are linkable allowing the user to cover any length of cable required… it is insufficient covering, say, only two-thirds of a trailing cable!

General FAQs

There is a fault with my product & I’d like a replacement?

D-Line take pride in the quality of our products, with rigorous quality checks in house. However if you’d like to discuss a quality issue, D-Line offer a 1-year guarantee for all purchases. Please provide receipt of payment (dated within 1 year) & images of the quality issue to: enquiries@d-line-it.com We’d be happy to assist.

I’ve chose the incorrect product & would like to return?

Please contact the point of purchase to discuss return requests, as all D-Line returns will need to be raised through our distributor partners.